HP8442

Powerbox HP8442

40 Outputs – 52 CAN Input – 12/24v – 200A+

1.400,00 

EXCL. VAT

Learn more below

Specifications:
  • +200A load (PCB tested to +400A).
  • Volt 12 & 24 Volt.
  • Active volt 5.7-32-volt DC.
  • Minimum St.by current consumption – 2.3 mA.
  • Weight: 543 Gram.
  • Box Size 183x119x21.
  • Box Type: Anodized Aluminum.
  • Connectors AMPSEAL .
  • Connector part number: 23pin: 770680-1 / 35pin:776164-1  / Gold Pins 770520-3.
23 High power Outputs can be controlled/monitored up to 7 levels:
  • Overload.
  • Load to Low.
  • Short Circuit.
  • Open Wire.
  • Active Status.
  • Error.
  • Current Reading.
16 Low power Outputs can be controlled/monitored up to 5 levels:
  • Overload.
  • Short Circuit.
  • Open Wire.
  • Active Status.
  • Error.
 1 Output:
  • Failure and Reset input/output. – Lamp / Switch.
 12 Inputs:
  • Toggle/momentary/latch.
  • Negative Input.
  • Positive Input.
  • Analog Input.
  • Pulse Input (PWM) max. 2Khz.
Outputs General:
  • High side (+ Output).
  • Low side (Gnd. Output).
  • PWM 10hz -2Khz (Pulse).
52 CAN Inputs:
  • 125kbit/s to 1.33 Mbit/s.
  • 11bit Identifier.
  • 29bit Identifier.
  • Fully configurable CAN.
Extra Features:
  • Flash upgrade only with USB Connected.
  • Special Menu “Blink Keypad” "Greyhill" and "HP9642".
  • Password Protection.
  • Debug Terminal Optional.
  CAN Export:
  • 5 Levels of CAN Export.
  • Fully Configurable CAN Export.
  • All Status´s export- Inputs, Outputs, Current, Status, Virtual.
  • Failures, Open Wire, Current, Temperature, PWM Status.
  • Firmware and S/N and more.
 Special Functions:
  • CAN Monitor Build in - Logger.
  • Flash Timers.
  • Delay Timers.
  • PWM.
  • Kill output function.
  • Start output Function.
  • Wiper Parking and logic.
  • Virtual (Logical Inputs).
  • Error Log.
  • Auto Reset Fuse.
  • Sequence Functions.
  • Automatic Power Down.
  • CAN Export of all statuses, inputs, outputs, current use, virtual, failure states.
  • Failure Output with Reset.
 8 Sequence Options:  
  • Set/Reset.
  • Toggle (Off -> A –> Off).
  • 3 Step Single (Off -> A - > B –> Off).
  • 4 Step Single (Off -> A - > B -> C –> Off).
  • 3 Step add (Off -> A -> A+B -> Off).
  • 4 Step add (Off -> A -> A+B -> A+B+C -> Off).
 20 Delay Timers:
  • On delay 0,1-1500 seconds.
  • On Time 0,1-6000 seconds.
  • Can be set in 5 groups also.
 5 Flash Timers:
  • Flash on-time 0,01-25 Sec.
  • Flash Off-time 0,01-25 Sec.
20 Virtual Channels:
  • It is possible to define some logical signals.
  • Based on And / Or /Nand / Nor and delay signals.
 Warranty:
  • 2 Years + Lifetime*
  • * Maximum 15 years
 Software Updates:
  • Free of charge.
  • PC Software - Free
  Regarding Current load of the Connector: AMPSEAL is specified to 17A Per Pin at 125 degrees Celsius. We have tested the current load with a temperature of 80 degree Celsius Each pin can have a load of 25A without any problems- For a load of 35A per pin its ok for 2 minutes Inrush is measured to be ok for 50A / 10 sec. In case of higher load, use double pin output or more.

Software

File Description
Fix: Wider width of entry field for display/selecting Input signals on High- and Low- power output page
Setting for BlinkMarine, Greyhill and HP CAN Switch Panels

Datasheet

File Description
Pin Out HP8442
Specifikations and feature list
HOW TO Setup Greyhill CAN open Keyboard
Request quote for product: Powerbox HP8442

Masterswitch HP8480

CAN Module HP8451

HP8442 CONNECTOR KIT

CAN Panel HP9642

Scroll to Top