HP8443

HP8443

POWERBOX – 16 Output – 12 Input – 52 CAN Input – 12/24v – 200A+ PWM

895,00 

Learn more below

  • We have launched a 16 Channel version of the Well known HP8442
Specification:
  • +200A load (PCB tested to +400A)
  • Voltage 12 & 24 Volt
  • Active voltage 5.7-32-volt DC
  • Minimum current consumption – 2.3 mA
  • Weight: 430 Gram
  • Box Size 141x119x21mm
  • Box Type: Anodized Aluminum
  • Connectors AMPSEAL Gold Type AMPSEAL
16 Outputs can be controlled/monitored up to 7 levels:
  • Overload
  • Load to Low
  • Short Circuit
  • Open Wire
  • Active Status
  • Error
  • Current Reading
12 Inputs:
  • Toggle/momentary/latch
  • Negative Input
  • Positive Input
  • Analog Input
  • Pulse Input (PWM) max. 2Khz
Output Types:
  • High side (+ Output)
  • Low side (Gnd. Output)
  • PWM 10hz -2Khz (Pulse)
52 CAN Inputs:
  • 125kbit/s to 1.33 Mbit/s
  • 11bit
  • 29bit
  • Fully configurable
CAN Export:
  • 5 Levels of CAN Export
  • Fully Configurable CAN Export.
  • All Status´s export- Inputs, Outputs, Current, Status
  • Failures, Open Wire, Current, Temperature, and more
Extra Features:
  • Flash upgrade only with USB Connected.
  • Special Menu “Blink Keypad” "Greyhill" and "HP9642".
  • Password Protection.
  • Debug Terminal Optional.
Special Functions:
  • CAN Monitor Build in - Logger.
  • Flash Timers.
  • Delay Timers.
  • PWM.
  • Kill output function.
  • Start output Function.
  • Wiper Parking and logic.
  • Virtual (Logical Inputs).
  • Error Log.
  • Sequence Functions.
  • Automatic Power Down.
  • CAN Export of all statuses, inputs, outputs, current use, virtual, failure states.
  • Failure Output with Reset.
 8 Sequence Options:  
  • Set/Reset.
  • Toggle (Off -> A –> Off).
  • 3 Step Single (Off -> A - > B –> Off).
  • 4 Step Single (Off -> A - > B -> C –> Off).
  • 3 Step add (Off -> A -> A+B -> Off).
  • 4 Step add (Off -> A -> A+B -> A+B+C -> Off).
 20 Delay Timers:
  • On delay 0,1-1500 seconds.
  • On Time 0,1-6000 seconds.
  • Can be set in 5 groups also.
 5 Flash Timers:
  • Flash on-time 0,01-25 Sec.
  • Flash Off-time 0,01-25 Sec.
20 Virtual Channels:
  • It is possible to define some logical signals.
  • Based on And / Or /Nand / Nor and delay signals.
 Warranty:
  • 2 Years + Lifetime*
  • * Maximum 15 years
 Software Updates:
  • Free of charge.
  • PC Software - Free
Regarding Current load of the Connector: AMPSEAL is specified to 17A Per Pin at 125 degrees Celsius. We have tested the current load with a temperature of 80 degree Celsius Each pin can have a load of 25A without any problems- For a load of 35A per pin its ok for 2 minutes Inrush is measured to be ok for 50A / 10 sec. In case of higher load, use double pin output or more.

To order this product, please click here.